16 ELEKTRO 8-9/2013 Transformers used in electric energy manufacturing and distribution network play significant role in our society as well. This device in the course of time goes through a certain evolution. The main consequence of the development, which even today is still running, is demand to improve design and specification of used materials and technologies. It is an indispensable aspect of improving the reliability and extending the life of all devices, especially in economic point of view. Therefore the article deals with a brief description of the deve-lopment of transformers. Next is described improvement in their design and highlighted are the most important milestones that affect the future of these devices.dostupné z: http://www.dexsil.com/uploads/docs/dtr_ 03_ 01.pdf [10] WISE Biodegradability Primer [on-line]. 2006 [cit. 2011-03-4], dostupné z:<http://www.wi-sesolutions.net/WISEbiodegradabilityprimer.pdf>[11] Oleje. [on-line], [cit. 2010-10-21], dostupné z <http://www2.zf.jcu.cz/~ moudry/databaze/Olej.htm>[12] ABDULLAHI, U. U. et al.: The potentials of palm oil as a dielectric fluid. In: PECon 2004. [s. l.], IEEE, 2004.[13] Biotemp. [on-line], 2005 [cit. 2010-11-12], dostupné z <http://www05.abb.com/global /scs -1cot252.ns f /ver i tydi splej /c1256b3c00492da685256c85006d74dc/$Fi-le/1LUS471050-LTE_ BIO.pdf>[14] Midel 7131. [on-line], 2010 [cit. 2010-11-12], dostupné z <http://www.midel.com/uploads/midel/documents/technical/MIDEL_ 7131_ Complete_ Binder_ of_ Data_ Sheets.pdf>[15] STOCKTON, D. P. et al.: Natural ester Trans-former fluids: Safety, reliability and environ-mental performance. In: PCIC ’07, IEEE, Calgary, 2007.[16] Dielectric fluids for transformer cooling. GE Energy Industrial Solutions [on-line], [cit. 2012-04-18], dostupné z: http://www.ge-Literatura:[1] HARLOW, J. H.: Electric power transformer engineering. CRC Press, USA, 2007.[2] WINDERS, J. J.: Power Transformers: Prin-ciples and Applications. Marcel Dekker, New York, 2002.[3] MENTLÍK, V. et al.: Diagnostika elektrických zařízení. BEN – technická literatura, Praha, 2008.[4] KULKARNI, S. V. – KHAPARDE, S. A.: Transformer Engineering: Design and Practice. Marcel Dekker, New York, 2004.[5] HEATHCOTE, M. J.: J&P Transformer book. Elsevier, Oxford, 2008.[6] About Transformer Control. Reinhausen Group [on-line], [cit. 2012-04-16], dostupné z: http://www.reinhausen.com/en/desktopdefault.aspx/tabid-23/261_ read-645/[7] Vídeňská úmluva. Ministerstvo životního pro-středí [on-line], [cit. 2012-04-16], dostupné z: http://www.mzp.cz/cz/videnska_ umluva_ mon-trealsky_ protokol_ dokument [8] Polychlorované bifenyly (PCB). ARNIKA [on--line], [cit. 2012-04-16], dostupné z http://arni-ka.org/polychlorovane-bifenyly-pcb [9] FISHER, D. J. – ROUSE FIELD, T. O.: De-termination of PCB in transformer oil CLOR- -N-OIL ™ KIT. [on-line], [cit. 2012-04-17], industrial.com/Newsletter/Dielectric_ Fluids_ for_ Transformer_ Cooling.pdf [17] Vegetable oils for liquid filled transformers. Electrical Insulation Magazine, 2002.[18] Pulp and Paper Application. [on-line], 2008 [cit. 2010-12-6], dostupné z <http://www. yokogawa.com/us/is/downloads/pdf/analyti-cal/APPNOTES/NR800_ A_ 002.pdf>[20] From Ripping saws to VACUTAP. REINHAU-SEN [on-line], [cit. 2012-04-19], dostupné z http://www.reinhausen.com/desktopdefault.aspx/tabid-82/categories-226/134_ view-163/catname-Publications [21] ETD – 90 let společnosti ve fotografiích a do-kumentech. ETD Transformátory, a. s. Christo, Plzeň, 2011.[22] KIML, M. W.: AC DC válka proudů. Dostupné z http://vtm.zive.cz/clanek/AC-DC-valka-proudu [23] BARTÁK, A. a kol.: Diagnostika poruch izo-lací elektrických strojů. SNTL, Praha, 1984.[24] MUŽÍK, P.: Nevíme o něm … aneb z pohle-du provozu a údržby ideální transformátor. Dostupné z http://www.trasfor.sk/documents/new_ clanek.pdf [25] http://www.mainepower.com/assets/albi-on%20auto%20transformer%20transportati-on%202-1-web.jpg. [cit. 2012-05-11][26] http://forca.ru/images/spravka/trans/rpn.jpg [cit. 2012-5-11] aktuality V ČR se ročně zrecyklu-je jen 5 % vyřazených mo-bilních telefonů. V České re-publice se ročně recyklu-je pouhých 5 % vysloužilých mobilních telefonů. Vyplý-vá to z informací zpracovate-lů elektroodpadu. Drtivá větši-na mobilních přístrojů tak kon-čí v popelnicích nebo doma v šuplíku. Až 80 % částí mobilního telefonu lze přitom recyklovat a opětovně využít. Starý mobil k recyklaci odevzdá jen zanedbatelné množ-ství Čechů. V celosvěto-vém měřítku jsou statistiky zrecyklovaných mobilů ješ-tě méně optimistické. Od-haduje se, že do recyklač-ních linek putuje maximál-ně 1 % všech mobilních telefonů. Jeden vyhoze-ný mobilní telefon přitom v přírodě dokáže obsahem škodlivých látek znehodnotit přes sto tisíc litrů vody. Předat jej k recyklaci je stále snazší, míst k tomu urče-ných každoročně přibývá.O podporu růstu množství zrecyklo-vaných mobilních telefonů se snaží i mobilní operátoři. Připouštějí ale, že zájem o ekologické zlikvidování starého mobilu není příliš velký. Nezájem Čechů o zpětný odběr mobilních telefonů v dů-sledku znamená obrovské množství ne-využitých materiálů, které by bylo mož-né získat jejich recyklací. Jde i o dra-hé kovy, jako je zlato, stříbro, palladium nebo platina. Mobilní telefon např. obsa-huje v průměru 24 mg zlata, a dokonce 205 mg stříbra.